Page 1 - COMSPHERE

COMSPHERE3550 SeriesData Service UnitsModels 3550 and 3551User’s GuideDocument No. 3550-A2-GB20-10

Page 2 - Models 3550 and 3551

Table of Contentsiii3550-A2-GB20-10 February 1995List of FiguresFigure Page2-1 Model 3550 Hardware Switch Location (shown without a TDM/Flex) 2-3. . .

Page 3 - Model 3550 and 3551

A-13550-A2-GB20-10 February 1995DSU MenuOverview A-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 4 - Important Safety Instructions

COMSPHERE 3550 Series Data Service UnitsA-2 February 1995 3550-A2-GB20-10

Page 5

DSU MenuA-33550-A2-GB20-10 February 1995

Page 6 - Government Requirements

COMSPHERE 3550 Series Data Service UnitsA-4 February 1995 3550-A2-GB20-10Continued from Page A-1.Press a function key to select one of the followingbr

Page 7

B-13550-A2-GB20-10 February 1995Configuration WorksheetsOverview B-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 8

Model 3550 or 3551 DSU Configuration Worksheet (1 of 2)(Full Menu Mode: Enabled)Date:_______________________________________________ Location:_

Page 9 - Appendix

Model 3550 or 3551 DSU Configuration Worksheet (2 of 2)(Full Menu Mode: Enabled)Backup ValueAuto Bckup Enab, DisabBackup Dir (Chang) (1–10)Fa

Page 10 - List of Figures

Model 3550 or 3551 DSU Configuration Worksheet (1 of 2)(Full Menu Mode: Disabled)Date:_______________________________________________ Location:

Page 11 - List of Tables

Model 3550 or 3551 DSU Configuration Worksheet (2 of 2)(Full Menu Mode: Disabled)MUX (Setup) ValueMUX Funct Enab, DisabShare DevA Enab, DisabPo

Page 12 - Table of Contents

COMSPHERE 3550 Series Data Service UnitsB-6 January 1995 3550-A2-GB20-10This page intentionally left blank.

Page 13

COMSPHERE 3550 Series Data Service Unitsiv February 1995 3550-A2-GB20-10List of TablesTable Page1-1 General Technical Specifications 1-4. . . . . . .

Page 14 - How to Use This Guide

C-13550-A2-GB20-10 February 1995Status Indicators andControl Panel MessagesOverview C-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 15 - Reference Documents

COMSPHERE 3550 Series Data Service UnitsC-2 February 1995 3550-A2-GB20-10Table C-1DSU Status IndicatorsLabelColor DescriptionOK Green Health and statu

Page 16 - About Your DSU

Status Indicators and Control Panel MessagesC-33550-A2-GB20-10 February 1995Control Panel MessagesThis section shows the screen format of messagesappe

Page 17 - Optional Features

COMSPHERE 3550 Series Data Service UnitsC-4 February 1995 3550-A2-GB20-10Table C-3(2 of 3)Device Health and Status MessagesMessage ConditionDial Tone:

Page 18 - Technical Specifications

Status Indicators and Control Panel MessagesC-53550-A2-GB20-10 February 1995Table C-3(3 of 3)Device Health and Status MessagesMessage ConditionMUX Dev

Page 19 - Criteria

COMSPHERE 3550 Series Data Service UnitsC-6 February 1995 3550-A2-GB20-10Table C-4Expanded Health and Status MessagesMessageConditionDial Attempt:nnTh

Page 20 - Specifications Criteria

Status Indicators and Control Panel MessagesC-73550-A2-GB20-10 February 1995Table C-5Subnetwork Health and Status MessagesMessageConditionDevic TDM/Fl

Page 21 - DSU Technical Specifications

COMSPHERE 3550 Series Data Service UnitsC-8 February 1995 3550-A2-GB20-10Progress MessagesTable C-6 describes the command progress messages,and Table

Page 22 - Table 1-3

Status Indicators and Control Panel MessagesC-93550-A2-GB20-10 February 1995Error MessagesTable C-8 describes the command error messages,Table C-9 des

Page 23 - Equipment Warranty

COMSPHERE 3550 Series Data Service UnitsC-10 February 1995 3550-A2-GB20-10Table C-9Dial Backup Error MessagesMessageNotify NMS1Condition ActionDBM: Bu

Page 24 - Out of Warranty

Table of Contentsv3550-A2-GB20-10 February 1995Table PageC-1 DSU Status Indicators C-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 25

Status Indicators and Control Panel MessagesC-113550-A2-GB20-10 February 1995Table C-10(1 of 3)TDM/Flex Error MessagesMessageCondition ActionAll Async

Page 26 - Installing the Model 3550 DSU

COMSPHERE 3550 Series Data Service UnitsC-12 February 1995 3550-A2-GB20-10Table C-10(2 of 3)TDM/Flex Error MessagesMessage ActionConditionInvalid timi

Page 27 - Hardware Straps

Status Indicators and Control Panel MessagesC-133550-A2-GB20-10 February 1995Table C-10(3 of 3)TDM/Flex Error MessagesMessage ActionConditionSync >

Page 28 - Table 2-1

COMSPHERE 3550 Series Data Service UnitsC-14 February 1995 3550-A2-GB20-10This page intentionally left blank.

Page 29 - Installing the DSU

D-13550-A2-GB20-10 February 1995Pin AssignmentsOverview D-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 30 - Connecting to the Network

COMSPHERE 3550 Series Data Service UnitsD-2 February 1995 3550-A2-GB20-10Table D-1Model 3550 – Digital (DDS) Network 8-Pin Cable Connector Pin Assign

Page 31 - Connecting to the NMS

Pin AssignmentsD-33550-A2-GB20-10 February 1995Table D-33600 Hubbing Device Pin AssignmentsPin # Signal Name Input/Output1 +5 Vdc Input2 DCOSD/CCIRD I

Page 32

COMSPHERE 3550 Series Data Service UnitsD-4 February 1995 3550-A2-GB20-10Figure D-3. Model 3551 DSU 25-Pin EIA-232/25-Pin V.35 Rear Connector Plate (3

Page 33

Pin AssignmentsD-53550-A2-GB20-10 February 1995Table D-5EIA-232/V.24 Connector Pin AssignmentsPinCircuit NameFunctionPinEIA-232CCITTFunction2 BA 103 T

Page 34 - Tributary DSU Addressing

COMSPHERE 3550 Series Data Service UnitsD-6 February 1995 3550-A2-GB20-10Figure D-4. V.35 Interconnect Cable (3000-F1-510)

Page 35 - Connecting the DSU to a DTE

COMSPHERE 3550 Series Data Service Unitsvi February 1995 3550-A2-GB20-10This page intentionally left blank.

Page 36 - Testing Connections

Pin AssignmentsD-73550-A2-GB20-10 February 1995Table D-6V.35 Connector Pin Assignments25-Pin Connector(Rear ConnectorPlate)34-Pin Connector (V.35 Inte

Page 37 - Other Tests

COMSPHERE 3550 Series Data Service UnitsD-8 February 1995 3550-A2-GB20-10Figure D-5. EIA-232-D Crossover Cable (4951-035F)

Page 38 - Installing the Model 3551 DSU

Pin AssignmentsD-93550-A2-GB20-10 February 1995Figure D-6. V.35 Crossover Cable (3211-178F)

Page 39 - Before You Begin

COMSPHERE 3550 Series Data Service UnitsD-10 February 1995 3550-A2-GB20-10This page intentionally left blank.

Page 40 - Switch Setting Function

E-13550-A2-GB20-10 February 1995Application ConfigurationsOverview E-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 41

COMSPHERE 3550 Series Data Service UnitsE-2 February 1995 3550-A2-GB20-10Figure E-1. Point-to-Point Application Configurations with Internal and Exter

Page 42

Application ConfigurationsE-33550-A2-GB20-10 February 1995Multipoint ApplicationsModel 3550 and Model 3551 DSUs also providehigh-speed multipoint circ

Page 43

COMSPHERE 3550 Series Data Service UnitsE-4 February 1995 3550-A2-GB20-10This page intentionally left blank.

Page 44

F-13550-A2-GB20-10 February 1995Equipment ListEquipmentFeature/Part No.G = Factory Install.F = Field Install.ComcodeModel 3550 Standalone DSUWith V.32

Page 45

COMSPHERE 3550 Series Data Service UnitsF-2 February 1995 3550-A2-GB20-10Equipment ComcodeFeature/Part No.G = Factory Install.F = Field Install.Model

Page 46 - DDS (or LADS) Network

vii3550-A2-GB20-10 February 1995PrefaceAbout This GuideThis user’s guide provides the information needed toinstall and operate your Model 3550 or 355

Page 47

Equipment ListF-33550-A2-GB20-10 February 1995Equipment* Part NumberAT&T Paradyne Field Service SparesFor Model 3550 DSU 2-Port TDM/FlexFor Mo

Page 48 - To Connect the SDCP to a DSU

COMSPHERE 3550 Series Data Service UnitsF-4 February 1995 3550-A2-GB20-10Equipment* Part NumberModel 3550 Digital (DDS) Network Interface Cable – RJ48

Page 49

Glossary-13550-A2-GB20-10 February 1995Glossaryactive core The core that is transmitting data. For example, the DBM is the active core whenthe unit is

Page 50 - Operating the DSU

COMSPHERE 3550 Series Data Service UnitsGlossary-2 February 1995 3550-A2-GB20-10CCITT The International Consultative Committee for Telegraphy and Tele

Page 51 - DCP and SDCP Operation

GlossaryGlossary-33550-A2-GB20-10 February 1995Device Test(Devic)A test that uses an internal test pattern generator built into the DSU to verify that

Page 52

COMSPHERE 3550 Series Data Service UnitsGlossary-4 February 1995 3550-A2-GB20-10errored second A performance measurement reported during Digital Test

Page 53 - Device Health and Status

GlossaryGlossary-53550-A2-GB20-10 February 1995multipoint circuit A data network circuit that uses multipoint transmission and consists of one control

Page 54 - Subnetwork Health and Status

COMSPHERE 3550 Series Data Service UnitsGlossary-6 February 1995 3550-A2-GB20-10session disruptive Application data may be disrupted when running a te

Page 55 - Backup Branch

Index-13550-A2-GB20-10 February 1995IndexAAbortselective, 4-9subnetwork, 4-9Abort Call failure message, C-6AC power, requirements, 1-4Active message,

Page 56 - Understanding Operating Modes

COMSPHERE 3550 Series Data Service UnitsIndex-2 February 1995 3550-A2-GB20-10CcablecrossoverEIA-232-D, figure, D-8V.35, figure, D-9EIA-232, connecting

Page 57 - Manual DDS Restoration

COMSPHERE 3550 Series Data Service Units viii February 1995 3550-A2-GB20-10Related DocumentsOther product documentation includes the following:3000-A2

Page 58 - Test Branch

IndexIndex-33550-A2-GB20-10 February 1995Ddata ratesDSU, 1-6V.32 DBM, 1-7DBMAggreg Exceeded error message, C-11Answering message, C-8Busy error messag

Page 59 - Bilateral Loopback

COMSPHERE 3550 Series Data Service UnitsIndex-4 February 1995 3550-A2-GB20-10Dir Empty, DBM error message, C-10directorydial backup, 4-17entry, and pa

Page 60 - Bit Error Rate Test

IndexIndex-53550-A2-GB20-10 February 1995FFac Alarm, C-4FacAlOnCMI, 5-21faceplate, Model 3611, 4-3Facil message, C-7Facility Alarm, C-2Fail message, C

Page 61 - Configuration Branch

COMSPHERE 3550 Series Data Service UnitsIndex-6 February 1995 3550-A2-GB20-10LLADS, 1-1connection, distances, table, 2-8network, connection, 2-7, 3-9o

Page 62 - Full Mode

IndexIndex-73550-A2-GB20-10 February 1995NNetL, DSU test, C-4networkaddress, 4-18addressing, link-level, 3-10compatibility, DSU, 1-6connection, 3-8DDS

Page 63 - Reconfiguring a TDM/Flex Port

COMSPHERE 3550 Series Data Service UnitsIndex-8 February 1995 3550-A2-GB20-10portasynchronous rates, TDM, 1-8capacity, 1-3DTE interface, TDM, 1-8rates

Page 64 - Changing the Poll List

IndexIndex-93550-A2-GB20-10 February 1995shock, 1-4signal level, 1-7Single Rate, 5-13single-port async/sync, 1-1specifications, technical, 1-3DSU, 1-6

Page 65 - Acquiring the Poll List

COMSPHERE 3550 Series Data Service UnitsIndex-10 February 1995 3550-A2-GB20-10UUL, 1-4Undersp Required error message, C-13Underspeed, 5-27, 5-28, 5-29

Page 66 - Entering a Telephone Number

1-13550-A2-GB20-10 February 1995About Your DSUOverview 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 67 - Assigning an Address

COMSPHERE 3550 Series Data Service Units1-2 February 1995 3550-A2-GB20-10• Diagnostic Control Panel control. TheModel 3550 DSU is controlled from its

Page 68 - Changing External Leads

About Your DSU1-33550-A2-GB20-10 February 19952-Port TDM/FlexThe 2-port TDM/Flex is a separate circuit card thatattaches to the Model 3550 DSU. It all

Page 69 - Messages Branch

COMSPHERE 3550 Series Data Service Units1-4 February 1995 3550-A2-GB20-10Table 1-1(1 of 2)General Technical SpecificationsSpecificationsCriteriaAPPROV

Page 70 - Configuring the Unit

February 1995COMSPHERE3550 SeriesData Service UnitsModels 3550 and 3551User’s GuideDocument No. 3550-A2-GB20-10ParadynePrinted on recycled paper

Page 71 - Set Configuration Options

About Your DSU1-53550-A2-GB20-10 February 1995Table 1-1(2 of 2)General Technical SpecificationsSpecifications CriteriaHEAT DISSIPATION (MAX.) AT 115 V

Page 72 - Example Using the DCP

COMSPHERE 3550 Series Data Service Units1-6 February 1995 3550-A2-GB20-10Table 1-2DSU Technical SpecificationsSpecifications CriteriaAPPLICATION Full-

Page 73

About Your DSU1-73550-A2-GB20-10 February 1995Table 1-3V.32 DBM Technical SpecificationsSpecifications CriteriaRINGER EQUIVALENCE NUMBER (REN) DBM opt

Page 74 - Configuration Option Tables

COMSPHERE 3550 Series Data Service Units1-8 February 1995 3550-A2-GB20-10Table 1-42-Port TDM/Flex Technical SpecificationsSpecifications CriteriaAPPLI

Page 75 - DSU Configuration Options

About Your DSU1-93550-A2-GB20-10 February 1995Out of WarrantyIf your equipment is out of warranty and you do nothave a maintenance support agreement,

Page 76

COMSPHERE 3550 Series Data Service Units1-10 February 1995 3550-A2-GB20-10This page intentionally left blank.

Page 77 - Table 5-2

2-13550-A2-GB20-10 February 1995Installing the Model 3550 DSUOverview 2-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 78 - Table 5-3

COMSPHERE 3550 Series Data Service Units2-2 February 1995 3550-A2-GB20-10circuit must be capable of supplying a minimum of2 amperes at 115 Vac. Refer

Page 79 - Table 5-5

Installing the Model 3550 DSU2-33550-A2-GB20-10 February 1995Figure 2-1. Model 3550 Hardware Switch Location (shown without a TDM/Flex)Table 2-1Model

Page 80

COMSPHERE 3550 Series Data Service Units2-4 February 1995 3550-A2-GB20-10Where to Place the DSUAs mentioned earlier, the DSU must be placed within6 fe

Page 81 - DBM Configuration Options

COMSPHERE 3550 Series Data Service UnitsA February 1995 3550-A2-GB20-10COMSPHEREModel 3550 and 3551Data Service UnitsUser’s Guide3550-A2-GB20-102nd Ed

Page 82 - (2 of 4)

Installing the Model 3550 DSU2-53550-A2-GB20-10 February 1995Power-Up RoutineWhen power is applied, the DSU:• Determines what options (DBM or TDM/Flex

Page 83 - (3 of 4)

COMSPHERE 3550 Series Data Service Units2-6 February 1995 3550-A2-GB20-10Connecting to the NMSA 3600 Hubbing Device is required to connect thecontrol

Page 84 - (4 of 4)

Installing the Model 3550 DSU2-73550-A2-GB20-10 February 1995Connecting to the DDS (or LADS) NetworkNOTEBefore connecting the DSU to theDDS network, e

Page 85 - Table 5-7

COMSPHERE 3550 Series Data Service Units2-8 February 1995 3550-A2-GB20-10Table 2-2LADS Connection DistancesData RateWire Gauge (AWG)Data Rate(kbps)19

Page 86 - General Configuration Options

Installing the Model 3550 DSU2-93550-A2-GB20-10 February 1995Tributary DSU AddressingTributary DSU addresses are user-definable, but takecare that the

Page 87

COMSPHERE 3550 Series Data Service Units2-10 February 1995 3550-A2-GB20-10Connecting the DSU to a DTEThe DSU’s rear panel has both a 25-pin EIA-232-D/

Page 88

Installing the Model 3550 DSU2-113550-A2-GB20-10 February 1995Connecting Port 2For the EIA-232 cable, install as described above.For the V.35 cable, i

Page 89

COMSPHERE 3550 Series Data Service Units2-12 February 1995 3550-A2-GB20-10Verifying DBM OperationIf a DBM is installed, test the tributary DBM fordial

Page 90 - Backup Configuration Options

3-13550-A2-GB20-10 February 1995Installing the Model 3551 DSUOverview 3-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 91

COMSPHERE 3550 Series Data Service Units3-2 February 1995 3550-A2-GB20-10Before You BeginThe COMSPHERE 3000 Series Carrier should alreadybe installed

Page 92

Safety InstructionsB3550-A2-GB20-10 February 1995Important Safety Instructions1. Read and follow all warning notices and instructions marked on the pr

Page 93

Installing the Model 3551 DSU3-33550-A2-GB20-10 February 1995Figure 3-1. Model 3551 DSU Switch and Jumper LocationsTable 3-1Model 3551 DSU Switch Sett

Page 94 - Table 5-11

COMSPHERE 3550 Series Data Service Units3-4 February 1995 3550-A2-GB20-10Table 3-2Model 3551 DSU Jumper StrapsStrapDesignationState ofJumper StrapFunc

Page 95

Installing the Model 3551 DSU3-53550-A2-GB20-10 February 1995Installing the DSUThe initial installation procedure for the Model 3551DSU requires the i

Page 96 - Table 5-12

COMSPHERE 3550 Series Data Service Units3-6 February 1995 3550-A2-GB20-104. Using a Phillips screwdriver, loosen the screwholding the circuit pack loc

Page 97 - Table 5-13

Installing the Model 3551 DSU3-73550-A2-GB20-10 February 19957. At the rear of the carrier, connect the appropriateDTE interface cable (EIA-232-D or V

Page 98 - Table 5-14

COMSPHERE 3550 Series Data Service Units3-8 February 1995 3550-A2-GB20-10Power-Up RoutineWhen power is applied, the DSU:• Determines what options (DBM

Page 99

Installing the Model 3551 DSU3-93550-A2-GB20-10 February 1995Connecting to the DDS (or LADS) NetworkNOTEBefore connecting the DSU to theDDS network, e

Page 100 - DSU Menu

COMSPHERE 3550 Series Data Service Units3-10 February 1995 3550-A2-GB20-10Tributary DSU AddressingTributary DSU addresses are user-definable, but take

Page 101

Installing the Model 3551 DSU3-113550-A2-GB20-10 February 1995To Connect the SDCP to a DSUFor the carrier-mounted Model 3551 DSU, the SDCPmust first b

Page 102

COMSPHERE 3550 Series Data Service Units3-12 February 1995 3550-A2-GB20-10Other TestsThe following lists the tests available on your DSU.Refer to the

Page 103 - System Administrator

COMSPHERE 3550 Series Data Service UnitsC February 1995 3550-A2-GB20-10Notices

Page 104 - Configuration Worksheets

4-13550-A2-GB20-10 February 1995Operating the DSUOverview 4-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 105 - TDM/Flex Installed

COMSPHERE 3550 Series Data Service Units4-2 February 1995 3550-A2-GB20-10Control Branch 4-19. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 106

Operating the DSU4-33550-A2-GB20-10 February 1995Figure 4-2. SDCP and Model 3551 DSU FaceplateBoth control panels have a 2-line, 16-character liquidcr

Page 107 - (Full Menu Mode: Disabled)

COMSPHERE 3550 Series Data Service Units4-4 February 1995 3550-A2-GB20-10F1 F2F3• The key returns you to the top-level menu, andterminates any wor

Page 108

Operating the DSU4-53550-A2-GB20-10 February 1995Expanded Health and StatusExpanded Health and Status (Expan) only appearsduring automatic dialing. It

Page 109

COMSPHERE 3550 Series Data Service Units4-6 February 1995 3550-A2-GB20-10Table 4-1Identity DescriptionsDescriptionInformation DisplayedModel: 3550 or

Page 110 - Control Panel Messages

Operating the DSU4-73550-A2-GB20-10 February 1995If the tributary DSU is to initiate the call, set thecontrol for Cllbk and the tributary for Pswrd.Ex

Page 111 - (circuit designations)

COMSPHERE 3550 Series Data Service Units4-8 February 1995 3550-A2-GB20-10Table 4-2Backup Branch Menu SelectionsCurrentBackup ModeBackupCommandEffectId

Page 112

Operating the DSU4-93550-A2-GB20-10 February 1995Test BranchThe Test branch provides extensive testing capabilitiesfor the DSU, the DDS circuit, the D

Page 113 - Message Condition

COMSPHERE 3550 Series Data Service Units4-10 February 1995 3550-A2-GB20-10NOTETo issue a Local Loopback to atributary DSU, the DSU must have aDBM inst

Page 114 - (3 of 3)

Safety InstructionsD3550-A2-GB20-10 February 1995Government RequirementsThe Federal Communications Commission (FCC) requires that instructions pertain

Page 115 - Condition

Operating the DSU4-113550-A2-GB20-10 February 1995Table 4-3Digital Test ResultsResultsInformation DisplayedTime: Running test timer. (The Clrselection

Page 116 - Table C-5

COMSPHERE 3550 Series Data Service Units4-12 February 1995 3550-A2-GB20-10Table 4-5Bit Error Rate Test ResultsResults Information DisplayedTime: Runni

Page 117 - Progress Messages

Operating the DSU4-133550-A2-GB20-10 February 19956. Select the mode:• Enable Full Mode (F2) – All configurationoptions will be displayed.• Disable Fu

Page 118 - Error Messages

COMSPHERE 3550 Series Data Service Units4-14 February 1995 3550-A2-GB20-105. Select Save (F1).The Save to screen appears.6. Select Activ (F1).The sele

Page 119

Operating the DSU4-153550-A2-GB20-10 February 199516. Select SAVE (F1).17. Save to Activ (F1).Command Complete appears to confirm that theconfiguratio

Page 120 - Condition Action

COMSPHERE 3550 Series Data Service Units4-16 February 1995 3550-A2-GB20-10To delete a network address (e.g., 3) from the poll list:ProcedureF1Chng Po

Page 121 - Message ActionCondition

Operating the DSU4-173550-A2-GB20-10 February 1995DirectoryThe DSU’s dial backup Directory (Dir) can store up toten telephone numbers (dial strings) s

Page 122

COMSPHERE 3550 Series Data Service Units4-18 February 1995 3550-A2-GB20-1010. Press the key to return to the Enter Dirscreen.11. Press the F3 key

Page 123

Operating the DSU4-193550-A2-GB20-10 February 19956. Select Save (F2).The DSU displays the address assigned along witha Command Complete message.If an

Page 124 - Pin Assignments

COMSPHERE 3550 Series Data Service Units4-20 February 1995 3550-A2-GB20-10Table 4-7Lead StatesSymbolMeaningOff (below text line)ON (above text line)Ch

Page 125

COMSPHERE 3550 Series Data Service UnitsE February 1995 3550-A2-GB20-10The DDS Service Order Number is 6.0Y. The jack configurations required are RJ48

Page 126

5-13550-A2-GB20-10 February 1995Configuring the UnitOverview 5-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 127

COMSPHERE 3550 Series Data Service Units5-2 February 1995 3550-A2-GB20-10Once loaded, the following Edit/Save submenuappears:F1Edit/Save:SAVE DSU DBMF

Page 128

Configuring the Unit5-33550-A2-GB20-10 February 1995Saving Configuration OptionsCAUTIONBe extremely careful when savingconfiguration options to avoids

Page 129

COMSPHERE 3550 Series Data Service Units5-4 February 1995 3550-A2-GB20-10F1Edit/Save:SAVE DSU DiagF2F3F1Chang Diag Opts:DSU DBM GenF2F3F1Diag Type:

Page 130

Configuring the Unit5-53550-A2-GB20-10 February 1995F1Port 1 DSU 9.6 TLocal RemotF2F3This example is now complete.Configuration Option TablesThis se

Page 131

COMSPHERE 3550 Series Data Service Units5-6 February 1995 3550-A2-GB20-10Table 5-1(1 of 2)DSU Configuration OptionsRate(Kbps): 9.6Next 64L

Page 132

Configuring the Unit5-73550-A2-GB20-10 February 1995Table 5-1(2 of 2)DSU Configuration OptionsRxElasStor: DisabNext Enab Disab Pr

Page 133

COMSPHERE 3550 Series Data Service Units5-8 February 1995 3550-A2-GB20-10Table 5-2Diagnostic (DSU) Configuration OptionsDiag Type: DisrNext Non

Page 134 - Application Configurations

Configuring the Unit5-93550-A2-GB20-10 February 1995Table 5-3Diagnostic (DBM) Configuration OptionsDiag Type: DisrNext NonD Disr

Page 135

COMSPHERE 3550 Series Data Service Units5-10 February 1995 3550-A2-GB20-10Table 5-4Diagnostic (External DBU) Configuration OptionsDiag Type: DisrNext

Page 136 - Multipoint Applications

i3550-A2-GB20-10 February 1995Table of ContentsPrefaceAbout This Guide vii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 137

Configuring the Unit5-113550-A2-GB20-10 February 1995Table 5-5(2 of 2)Diagnostic (General) Configuration OptionsTribTimOut: 0:10Next Chang

Page 138 - Equipment List

COMSPHERE 3550 Series Data Service Units5-12 February 1995 3550-A2-GB20-10Table 5-6(1 of 4)DBM Configuration OptionsRate(Kbps): 9.6Next 14.4

Page 139 - F = Field Install

Configuring the Unit5-133550-A2-GB20-10 February 1995Table 5-6(2 of 4)DBM Configuration OptionsSingle Rate: YesNext Yes No PrevSi

Page 140 - Equipment* Part Number

COMSPHERE 3550 Series Data Service Units5-14 February 1995 3550-A2-GB20-10Table 5-6(3 of 4)DBM Configuration OptionsCall Setup:NoneNext None

Page 141

Configuring the Unit5-153550-A2-GB20-10 February 1995Table 5-6(4 of 4)DBM Configuration OptionsV.13 Signl: Enab for MPTC and MPTT; Disab for other con

Page 142 - Glossary

COMSPHERE 3550 Series Data Service Units5-16 February 1995 3550-A2-GB20-10Table 5-7External DBU Configuration OptionsExtBU: NoneNext Ansr

Page 143

Configuring the Unit5-173550-A2-GB20-10 February 1995Table 5-8(1 of 4)General Configuration OptionsDTE Port: EIA232Next EIA232 V.35

Page 144

COMSPHERE 3550 Series Data Service Units5-18 February 1995 3550-A2-GB20-10Table 5-8(2 of 4)General Configuration OptionsLSD Lead: StdNext Std

Page 145

Configuring the Unit5-193550-A2-GB20-10 February 1995Table 5-8(3 of 4)General Configuration OptionsLL by DTE: DisabNext Enab Disab

Page 146

COMSPHERE 3550 Series Data Service Units5-20 February 1995 3550-A2-GB20-10Table 5-8(4 of 4)General Configuration OptionsDTR Alarm: DisabNext En

Page 147

COMSPHERE 3550 Series Data Service Unitsii February 1995 3550-A2-GB20-104. Operating the DSUOverview 4-2. . . . . . . . . . . . . . . . . . . . . . .

Page 148

Configuring the Unit5-213550-A2-GB20-10 February 1995Table 5-9(1 of 2)Backup Configuration OptionsAuto Bckup:DisabNext Enab Disab

Page 149

COMSPHERE 3550 Series Data Service Units5-22 February 1995 3550-A2-GB20-10Table 5-9(2 of 2)Backup Configuration OptionsRestorTimOut: 5mNext Cha

Page 150

Configuring the Unit5-233550-A2-GB20-10 February 1995Table 5-10MUX (Setup) Configuration OptionsMUX Funct: Disab for MPTC; Enab for all other configur

Page 151

COMSPHERE 3550 Series Data Service Units5-24 February 1995 3550-A2-GB20-10Table 5-11(2 of 4)MUX (Port) Configuration Options*Async Rate: =SyncNext

Page 152

Configuring the Unit5-253550-A2-GB20-10 February 1995Table 5-11(3 of 4)MUX (Port) Configuration Options*TxCarrSel: ConstNext Const Cntrl

Page 153

COMSPHERE 3550 Series Data Service Units5-26 February 1995 3550-A2-GB20-10Table 5-11(4 of 4)MUX (Port) Configuration Options*Elast Stor: DisabNext

Page 154

Configuring the Unit5-273550-A2-GB20-10 February 1995Table 5-12Port Speed (DSU) Configuration OptionsPrt1( 9.6): 9.6Next 64 56 48

Page 155

COMSPHERE 3550 Series Data Service Units5-28 February 1995 3550-A2-GB20-10Table 5-13Port Speed (DBM) Configuration OptionsPrt1( 9.6): 9.6Next 1

Page 156

Configuring the Unit5-293550-A2-GB20-10 February 1995Table 5-14Port Speed (External DBU) Configuration OptionsPrt1( 9.6): 9.6Next 64 56

Page 157

COMSPHERE 3550 Series Data Service Units5-30 February 1995 3550-A2-GB20-10This page intentionally left blank.